Firmware change information, Home Assistant pairing, guide, template, tutorial and help for...

Grid Connect Series 3 Smart Plug with Energy Meter (PC191BKHA)

Grid Connect Series 3 Smart Plug with Energy Meter
Information

Vendor: Arlec

Chip: BK7231N

Board: CB2S

Detailed: 1

Keywords: BL0937, PC191-A4-G, 20210105-G

Device Template
Pins
- P6 is BL0937CF1 on channel 0
- P7 is BL0937CF on channel 0
- P8 is Rel on channel 1
- P10 is WifiLED_n on channel 0
- P11 is Btn on channel 1
- P24 is BL0937SEL on channel 0
- P26 is LED on channel 1
- Flags are set to 134218752
- StartupCommand is set to backlog startDriver NTP; startDriver BL0937; SetupEnergyStats 1 300 10; PowerSave 1; PowerSave_WFI 1; TelePeriod 300
Futher reading

Read detailed flashing guide and get help in device topic: English guide, see also Polish guide

Return to devices list.